Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13775721

- Product Categories
- Friendly Links
Information Name: | Guangzhou FCL impermeability of concrete corrosion protection agent |
Published: | 2015-07-13 |
Validity: | 730 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Guangzhou FCL impermeability of concrete corrosion protection agent Guangzhou FCL impermeability of concrete corrosion protection agent is a colorless, odorless, non-toxic, can be deep penetration of high-tech, environment-friendly concrete waterproofing material. FCL impermeability of concrete anti-corrosion protective coating is not just concrete waterproofing agent, it is concrete protective agent, it is acid and alkali, corrosion resistance, resistance to temperature change! But also the destruction of concrete resistance to chloride ion erosion. Instructions: normal concrete building before spraying to ensure concrete surface clean, dry or slightly moist state, the construction temperature should be between 4-50 ℃, relative humidity of 10% - 90% Optimum. Stir impermeability of concrete corrosion protection agent before spraying (greater than one minute), not mixed with any other liquid. Spray evenly with a sprayer or brush first pass, saturation, if the partial drying process too quickly, you can immediately fill spray, etc. appear semi-dry concrete surface when the overall repeatability spraying the second time. If white crystalline residue is a normal phenomenon occurs, can be erased with water. Normal spraying area per gallon to cover 12 to 20 square meters (3-5 sqm / kg), spraying the area depends on how much penetration and porosity of the concrete. Construction completed within 24 hours to keep the concrete surface is not frozen water washout, 5-7 days at room temperature curing, before backfill or cover other substances. Not on the surface of aluminum products, glazed or glass corrosion impermeability use concrete protection agents, corrosion may otherwise occur; In case of contact, rinse with fresh water. Defective concrete building when the concrete construction defects (holes or cracks) is large, need concrete impermeability corrosion protection agent mixed with cement mortar to fill the defect. When concrete defect is too large and has water leaking, the first dedicated plugging material into the crack or hole, blocking the flow, then concrete impermeability corrosion protection agents mixed with cement mortar to fill the defect closure. For better results, we recommend sealing after the normal construction methods for spraying concrete impermeability corrosion protection agent. Scope: ★ anti-surface roads and bridges, tunnels, airport runways, power plant corrosion impermeability ★ sewage treatment plants, paper mills, water plant corrosion impermeability, anti-moss and biological adsorption ★ airport runways, parking, hangar impermeability corrosion charring, wear ★ military engineering cavern, civil air defense projects, underground space moisture, corrosion impermeability ★ dams, culverts, anti charring ★ pharmaceutical plant, food processing plant aseptic processing ★ reinforcement, protection and restoration of cultural relics monuments, monuments prevent corrosion powder Main functions and advantages of colorless or white, odorless, non-toxic and non-flammable environmentally friendly products corrosion impermeability, moisture, mildew and other functions, and can enhance the strength of concrete effective against weathered concrete, powder and dust damage the concrete can resist acid, alkali and oxidation corrosion material does not affect the concrete surface color and structure, keeping concrete permeability easy to operate, wet concrete Jieke Construction (no clear water) can be sealed 0.3mm The following fracture, with self-healing capabilities become a permanent part of the concrete when the concrete to produce new minor cracks again, the concrete structure with life. Executive Standard: Q / WDY04-2010 Note: Do not seal asphalt, metal, glass and wood, if the contact immediately rinse with water to clean construction tools to prevent other chemicals mixed into a protective agent, the impact of the use of protective agents the effect of the product can not be added to water use, after completion of construction extra protection agent must be enclosed storage Construction conditions: ambient temperature: 4.4 ℃ --35 ℃; Relative Humidity: 10% -90% of the product should be closed, cool area storing, stacking height must not exceed 3 layers, the product packing 20kg, non-toxic, non-flammable, non-explosive, safe transport. Guangzhou Tel: 136-0049-7358 charge: Wang Guangzhou FCL impermeability of concrete corrosion protection agent |
Admin>>>
You are the 8983 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Corning waterproof materials Engineering Limited All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8983 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Corning waterproof materials Engineering Limited All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility